PDV Optics provides ODN passive components, PLC splitters, fiber distribution boxes, quick connectors, drop cables, FTTR solutions, building broadband, and community fiber networks...
Guide The AC and pulsed DC sensitive residual current monitor RCM420 (Type A) from Bender is designed for fault and residual current monitoring in earthed power supply systems (TN/ TT systems) where an
Guide By using a VAC/Bender DI sensor integrated into an IC-CPD or wall box, customers can save the high costs of installing a type B RCCB to provide all-current sensitivity and electrical safety at low cost.
Guide The Bender solution is based on the residual current sensor CCE4400, which is able to measure residual currents from DC up to 2 kHz with a resolution better than 0.2 mA.
Guide The AC/DC sensitive residual current monitor RCMA420 is designed for use in earthed systems (TN and TT systems) where DC and AC fault currents may occur.
Guide High-precision analog output RCMU for Type B residual current detection. Detects AC, pulsating DC, and smooth DC fault currents per IEC 62955. Ideal for EV charging stations.
Guide In line with paragraph 531.3.2 of HD 60364-5-53;2015 (Selection and erection of electric equipment), the electrical system must be designed in such a way that the leakage current does not exceed 0.3 times
Guide If the fault memory behaviour of relay K1 or K2 is activated, the device must be reset by pressing the "T" button. The MRCD module automatically checks the measuring current transformer and the function
Guide The RC223 residual current release, which can be combined with the Tmax T3, T4 four-pole circuit-breakers in the fixed or plug-in version, is the most advanced solution in the whole residual current
Guide An RCD (residual current device) is designed to automatically disconnect the power supply when a residual current occurs, within such a short period of time that people are protected from the
Guide AC/DC sensitive residual current monitors for monitoring alternating currents, pulsating and smooth direct fault currents with type B/B+ tripping characteristics in accordance with IEC 60755.
Guide This reference design detects milliampere-level AC and DC ground fault currents for residual current detection (RCD) and ground fault current interrupters (GFCI), targeted to meet timing and accuracy
Guide The AC/DC sensitive residual current monitor RCMA423 is designed for use in earthed systems (TN and TT systems) where DC and AC fault currents may occur.